T049147
Bourns Inc.

GAS DISCHARGE TUBE

  • Voltage - DC Spark Over (Nom): -
  • Impulse Discharge Current (8/20µs): -
  • Tolerance: -
  • Number of Poles: -
  • Fail Short: -
  • Mounting Type: -
  • Package / Case: -
pacchetto: -
Azione7.974
-
-
-
-
-
-
PMT3(310)25014
Littelfuse Inc.

GDT 250V 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
pacchetto: Axial Cylinder, 3 Lead (T-Shape)
Azione4.590
20000A (20kA)
-
3
No
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
GTCR38-231M-P10-FS
Littelfuse Inc.

GDT 230V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Radial Cylinder, 3 Lead
pacchetto: Radial Cylinder, 3 Lead
Azione5.166
10000A (10kA)
±20%
3
Yes
Through Hole
Radial Cylinder, 3 Lead
SL1024B090C
Littelfuse Inc.

GDT 90V 20KA

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione5.940
20000A (20kA)
-
3
No
User Defined
Cylinder No Lead, 3 Terminal
SL1024A450C
Littelfuse Inc.

GDT 450V 10KA

  • Voltage - DC Spark Over (Nom): 450V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione2.700
10000A (10kA)
-
3
No
User Defined
Cylinder No Lead, 3 Terminal
LT450SM
Littelfuse Inc.

GDT 450V SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 450V
  • Impulse Discharge Current (8/20µs): -
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
pacchetto: 2-SMD Cylinder Square End
Azione7.920
-
-
2
No
Surface Mount
2-SMD Cylinder Square End
SL1122A250
Littelfuse Inc.

GDT 250V 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Radial Cylinder, 3 Lead
pacchetto: Radial Cylinder, 3 Lead
Azione3.510
10000A (10kA)
-
3
No
Through Hole
Radial Cylinder, 3 Lead
2097-220-DLF
Bourns Inc.

GDT 2200V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2200V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione7.020
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
CG2250LSN
Littelfuse Inc.

GDT 250V 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione3.402
20000A (20kA)
-
2
No
Through Hole
Axial Cylinder
CG2145LS
Littelfuse Inc.

GDT 145V 20KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 145V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: Axial Cylinder, Radial SMT Bend
pacchetto: Axial Cylinder, Radial SMT Bend
Azione5.958
20000A (20kA)
-
2
No
Surface Mount
Axial Cylinder, Radial SMT Bend
CG2350LSNTE
Littelfuse Inc.

GDT 350V 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione7.218
20000A (20kA)
-
2
No
Through Hole
Axial Cylinder
CG2470
Littelfuse Inc.

GDT 470V 20KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
pacchetto: Cylinder No Lead
Azione8.460
20000A (20kA)
-
2
No
User Defined
Cylinder No Lead
2046-25-C2FLF
Bourns Inc.

GDT 250V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione2.358
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
ST-0840-BLB-STD
Bourns Inc.

GDT 840V 12% THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 840V
  • Impulse Discharge Current (8/20µs): -
  • Tolerance: ±12%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione2.106
-
±12%
2
No
Through Hole
Axial Cylinder
2026-60-A1LF
Bourns Inc.

GDT 600V 20% 20KA

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione2.160
20000A (20kA)
±20%
3
No
User Defined
Cylinder No Lead, 3 Terminal
2036-47-ALF
Bourns Inc.

GDT 470V 20% 10KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione4.896
10000A (10kA)
±20%
3
No
User Defined
Cylinder No Lead, 3 Terminal
2056-35-B2FLF
Bourns Inc.

GDT 350V 20% 5KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione4.752
5000A (5kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2027-07-BT1LF
Bourns Inc.

GDT 75V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione7.686
10000A (10kA)
±20%
2
No
Through Hole
Axial Cylinder
2056-25-B2LF
Bourns Inc.

GDT 250V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
pacchetto: Axial Cylinder, 3 Lead (Radial Bend)
Azione3.906
5000A (5kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2031-23T-SM-RP3LF
Bourns Inc.

GDT 185V 1KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 185V
  • Impulse Discharge Current (8/20µs): 1000A (1kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
pacchetto: 2-SMD Cylinder Square End
Azione3.924
1000A (1kA)
-
2
No
Surface Mount
2-SMD Cylinder Square End
2027-15-SMLF
Bourns Inc.

GDT 150V 15% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
pacchetto: 2-SMD Cylinder Square End
Azione2.916
10000A (10kA)
±15%
2
No
Surface Mount
2-SMD Cylinder Square End
2093-100-SM-RPLF
Bourns Inc.

GDT 1000V 20% 3KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 1000V
  • Impulse Discharge Current (8/20µs): 3000A (3kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
pacchetto: 2-SMD Cylinder Square End
Azione3.562
3000A (3kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2035-35-SMLF
Bourns Inc.

GDT 350V 15% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
pacchetto: 2-SMD Cylinder Square End
Azione8.424
5000A (5kA)
±15%
2
No
Surface Mount
2-SMD Cylinder Square End
2057-09-BLF
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione5.976
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
GTCA26-141M-R05
Littelfuse Inc.

GDT 140V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 140V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione20.700
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2026-09-CLF
Bourns Inc.

GDT 90V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
pacchetto: Axial Cylinder, 3 Lead (T-Shape)
Azione12.024
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
SL1003A250C
Littelfuse Inc.

GDT 250V 10KA

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead, 3 Terminal
pacchetto: Cylinder No Lead, 3 Terminal
Azione24.048
10000A (10kA)
-
3
No
User Defined
Cylinder No Lead, 3 Terminal
GTCS25-900M-R05-2
Littelfuse Inc.

GDT 90V 20% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
pacchetto: 2-SMD Cylinder Square End
Azione15.810
5000A (5kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
B88069X4930S102
EPCOS (TDK)

GDT 230V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione19.332
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-7200-CLT-STD
Bourns Inc.

GDT 7200V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 7200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
pacchetto: Axial Cylinder
Azione52.128
5000A (5kA)
±20%
2
No
Through Hole